1Z0-344 JD Edwards EnterpriseOne Configurable Network Computing 9.2 Implementation Essentials Practice Questions
Prepare for 1Z0-344 with more than an answer.
- Exam fee
- $245 USD
- Level
- Implementation Specialist
- Valid for
- Certification does not expire but may require recertification for major version updates
Domains covered on the exam 5
- Configurable Network Computing (CNC) Foundation and Terminology20%
- Package Management20%
- Security15%
- Install, Upgrade, and Configure25%
- Architecture, Performance and Troubleshooting20%
- 1
Case Study:
A large distribution company, Global Logistics Inc., is in the final stages of an Application Upgrade from 9.1 to 9.2. The project has been complex, involving significant customizations and data volume. The go-live weekend is approaching, and the CNC lead needs to present the final plan for the production cutover to the steering committee.
The current production environment (9.1) consists of two enterprise servers, four web servers, and a database server. The new 9.2 environment has been built in parallel with identical server counts. The final data migration has been practiced and is well-understood. The key requirement from the business is to minimize the production downtime and have a clear rollback plan.
The CNC team has proposed a plan that involves running the Installation and Upgrade Workbench on the production environment during the go-live weekend. This includes table conversions and running various Table Conversion UBEs. After the workbench completes, they will deploy the final 9.2 full package.
The steering committee is concerned about the risk associated with running the workbench on their live production data for the first time. They ask the CNC lead for an alternative approach that would reduce the risk and potentially shorten the cutover window. Which of the following represents the best practice and lowest-risk approach for this scenario?
Show answer details
Correct answer: C
The lowest-risk and most efficient approach is to de-risk the upgrade process from the go-live weekend itself. By taking a fresh copy of production data and running the entire Installation Workbench and table conversion process in the parallel 9.2 environment ahead of time, the team validates the entire technical upgrade on the real data set. The actual go-live cutover is then reduced to a much shorter and less risky process: a final, small delta data migration and re-pointing the production web servers to the already-upgraded 9.2 application servers and database. This significantly minimizes downtime and provides a proven rollback path (the original 9.1 system).
- 2
A developer has created a new User Defined Object (UDO) of type 'Composite Application Framework' (CafeOne layout) and shared it. A business analyst needs to be able to view and use this CafeOne layout, but should not be able to modify or re-share it. Which combination of permissions must be granted to the business analyst's role for this specific UDO?
Show answer details
Correct answer: C
UDO security is managed at a granular level. To meet the requirement, the business analyst's role needs explicit permissions for the specific UDO. 'View' permission allows the user to see and use the CafeOne layout. Explicitly setting 'Modify' and 'Create' to Deny (or leaving them ungranted, which defaults to deny) prevents the user from changing the layout or creating new ones. This combination grants the required read-only access. Action Security and Feature Security are different layers of security and do not control the specific View/Modify permissions on an individual UDO.
- 3
A CNC administrator is investigating a failed server package build for an update package. The
R9622c.pdfreport indicates that the build was successful, but developers report that a newly modified Business Service (BSSV) object is not functioning as expected on the server. Thejde.loganddebug.logshow no errors during the build process. Which log file is the MOST critical to examine to diagnose why the BSSV object was not correctly compiled and linked into the server package?Show answer details
Correct answer: B
The
BuildLog.txtcontains the detailed output from the compiler and linker for server-side objects, including Business Services (BSSV). WhileR9622c.pdfprovides a high-level summary,BuildLog.txtwill contain the specific compiler errors or linker warnings that would explain why the BSSV object failed to build correctly, even if the overall package process completed.ClientPkgBuild.logis for client-side business functions.jas.logrelates to the HTML server runtime, not the package build.PkgHistory.logtracks package deployment history, not build details. - 4
A financial institution has enabled Row Security for the F0911 (Account Ledger) table to restrict access based on Business Unit. A custom UBE report, R550911, is designed to process all ledger entries. However, when users run this report, it processes records from all business units, effectively bypassing the configured Row Security. What is the most likely reason for this behavior?
Show answer details
Correct answer: B
By default, UBEs can be configured to ignore Row Security. This is a common setting for batch processes that need to process data across the entire dataset, regardless of the user's interactive security. This property is set on the specific UBE version level in the Batch Versions application (P98305W). If this flag is checked, the UBE will not apply the row security rules defined for the user who submitted the job. The other options are less likely causes for a specific UBE to bypass security while it is active for other applications.
- 5
A CNC team is deploying a multi-foundation environment to support parallel development on two different Tools Releases (9.2.5 and 9.2.6). Which TWO configurations are essential on the Deployment Server to ensure that each foundation is isolated and uses the correct set of tools and system files? (Select TWO).
Show answer details
Correct answer: A, C
Each Tools Release foundation requires its own independent set of system tables (e.g., F9860, F98611) to store its specific configuration, object specifications, and metadata. Sharing these tables would lead to corruption and instability.
The Release Master (F00941) table on the Deployment Server defines the location of the system (
misc) and Bitness directories for each foundation. Creating separate records (e.g., E920_1, E920_2) is critical for directing clients and servers to the correct binaries and configuration files for their respective Tools Release. - 6
A junior administrator reports that after promoting a set of User Defined Objects (UDOs) to the next status in the Object Management Workbench (OMW), users are still unable to see the changes. The UDOs are of type 'Grid Format' and 'Query'. The administrator confirms that the UDOs have been shared with the correct roles and that users have refreshed their sessions. What is the most likely cause of this issue?
Show answer details
Correct answer: B
For UDOs like Grid Formats and Queries, simply promoting them in OMW and sharing them is not enough to make them available in target environments. The changes are stored in Central Objects and must be deployed to the target servers (Enterprise and HTML) via an update package. Once the package is deployed, the changes will be reflected for users in that environment. Publishing is a separate concept related to making UDOs available for modification or use in other UDOs.
- 7
During a Tools Release upgrade, a CNC administrator is tasked with running the Installation Workbench. The process fails during the 'Table and Index Creation' step. Which is the MOST effective first step to troubleshoot this failure?
Show answer details
Correct answer: B
The
jdeplan.logfile, located in the root of the JDEdwards installation directory on the Deployment Server, contains the detailed step-by-step logging of the Installation Workbench process. When a failure occurs, this log will contain the specific error messages, such as SQL errors for table creation, permission issues, or data source connection problems, that are necessary to diagnose the root cause. The other logs are less specific to the workbench process itself. - 8
A global manufacturing firm is deploying a new Tools Release to their JD Edwards 9.2 multi-foundation environment. During the installation on the Deployment Server, the process fails. The CNC administrator is tasked with identifying the root cause. The initial review of the
jde.logprovides a generic error message. To get detailed, step-by-step information about the installer's activities, including file copy operations and registry updates, which specific log file should be examined first?Show answer details
Correct answer: A
The
InstallAction.logis the primary log file for troubleshooting Tools Release installations. It provides a verbose, chronological record of every action the installer attempts, such as file copies, DLL registrations, and configuration file updates, making it the most effective tool for diagnosing installation failures. Whilejde.logshows general EnterpriseOne errors, it lacks the installer-specific detail found inInstallAction.log.debug.logis for runtime issues, not installation.package buildlogs are irrelevant to a Tools Release installation. - 9
A CNC administrator is configuring a high-availability JD Edwards EnterpriseOne environment. They have set up a cluster for the logic/application servers. To ensure that user sessions are properly managed and can fail over between nodes, which specific kernels must be configured to be cluster-aware (i.e., cluster-enabled in the jde.ini)? (Select TWO)
Show answer details
Correct answer: A, B
For proper session failover in a clustered environment, the Security Kernel and the Call Object Kernel are the primary kernels that need to be cluster-enabled. The Security Kernel manages user session information, and making it cluster-aware ensures that authentication state is replicated across nodes. The Call Object Kernel handles business function calls and state, and clustering it allows user sessions to continue processing on a different node after a failover. The UBE and Workflow kernels are not directly involved in maintaining the interactive user session state.
- 10
A pharmaceutical company must comply with strict auditing requirements. They need to ensure that any changes to critical processing options for the Sales Order Entry application (P4210) are tracked. The CNC administrator has enabled auditing on the Processing Options Master table (F983051). However, auditors report that they cannot see 'before' and 'after' values for the changes. What is the most likely reason for this issue?
Show answer details
Correct answer: A
The Processing Options Master table (F983051) stores its data in a BLOB (Binary Large Object) field. The native JD Edwards auditing functionality cannot decode the data within BLOB fields to capture individual 'before' and 'after' values for specific processing option changes. It can only record that the BLOB field itself was changed. Therefore, even with auditing enabled, the detailed change data is not available. The other options are incorrect as auditing is supported on this table (just not the BLOB content), the user's permissions are irrelevant to how the audit data is captured, and the security kernel is not the component responsible for writing audit table records.
