500-174 Practice Questions
Prepare for 500-174 with more than an answer.
- Exam fee
- $300 USD
- Level
- Specialist
- Valid for
- 3 years
Domains covered on the exam 5
- Information Gathering for FlexPod Solutions10%
- FlexPod Design10%
- FlexPod Configuration34%
- FlexPod Administration26%
- FlexPod Troubleshooting20%
- 1
In a FlexPod environment, what is the primary difference between a SAN LIF and a NAS LIF on a NetApp ONTAP cluster?
Show answer details
Correct answer: C
This is the core difference. When creating a Logical Interface (LIF) on a Storage Virtual Machine (SVM), you specify which data protocols it will serve. SAN LIFs are configured to handle block-level protocols like FC, FCoE, iSCSI, or NVMe-oF. NAS LIFs are configured for file-level protocols like NFS and CIFS/SMB.
- 2
An administrator observes intermittent packet loss on a vPC link between a UCS Fabric Interconnect and a Nexus 9000 switch. A
show vpc consistency-parameterscommand on the Nexus switch reveals a mismatch for the 'Spanning Tree Port Type' parameter. What is the most effective way to resolve this inconsistency?Show answer details
Correct answer: C
A common cause for this vPC Type 1 consistency error is when the Spanning Tree port type is not configured identically on the vPC member ports on both peer switches. For links to devices like Fabric Interconnects, the best practice is to configure the port-channel as a network port using
spanning-tree port type network. Applying this command consistently to the port-channel interface on both vPC peers will resolve the mismatch. - 3
A FlexPod administrator is configuring NetApp AutoSupport. The company's security policy requires that all management traffic, including support notifications, must be sent over a secure, encrypted channel. Which transport protocol should be selected for AutoSupport to meet this requirement?
Show answer details
Correct answer: C
HTTPS (HTTP Secure) is the standard protocol for sending AutoSupport messages. It uses TLS/SSL to encrypt the connection between the ONTAP system and NetApp's support backend, ensuring the confidentiality and integrity of the transmitted data.
- 4
True or False: A single UCS Service Profile Template can be used to deploy configurations to both B-Series blade servers and C-Series rack servers simultaneously.
Show answer details
Correct answer: B
This statement is false. Service Profile Templates are specific to a server form factor (blade vs. rack) due to differences in hardware like adapters and local storage configurations. An administrator must create separate templates for B-Series and C-Series servers.
- 5
A new UCS blade is unable to boot from its FC SAN LUN. The administrator confirms the following:
- The vHBA initiator WWPN is correctly zoned to the NetApp FC LIF target WWPN on the MDS switches.
- The LUN is mapped to the correct initiator group (igroup) on the NetApp SVM.
- The boot LUN is visible within the UCS KVM's UEFI boot options, but the OS fails to load.
Which component is the most likely source of the problem?
graph TD UCS_Blade[UCS B200 Blade] -- vHBA --> FI[Fabric Interconnect] FI -- FC Uplink --> MDS[MDS 9148 Switch] MDS -- FC --> NetApp[NetApp AFF A400] UCS_Blade -- KVM --> Admin[Admin Workstation] Admin -- Sees_LUN{LUN Visible in UEFI} -- Fails --> OS_Boot[OS Boot Failure]Show answer details
Correct answer: C
The Boot Policy in the UCS Service Profile dictates the order in which the server attempts to boot from various devices. It also specifies the primary and secondary SAN boot targets (WWPNs). If the LUN is visible but the OS won't load, it's highly probable that the boot policy is either pointing to the wrong LUN (if multiple are visible), has the wrong boot target WWPN specified as primary, or the boot order is incorrect, causing it to try other devices first. The visibility of the LUN confirms Layers 1-3 of the SAN are working; the boot failure points to a logical configuration issue like the boot policy.
- 6
A financial services client is deploying a new FlexPod Datacenter with NetApp AFF A250, Cisco UCS B200 M6 blades, and Nexus 93180YC-FX switches. To comply with strict data sovereignty regulations, they must ensure that all NFSv4.1 traffic for their European user base is handled exclusively by a dedicated SVM and its associated LIFs. Which ONTAP feature is the most direct and effective way to enforce this traffic segmentation at the network level?
Show answer details
Correct answer: A
IPspaces in ONTAP provide complete network stack separation, including routing tables, port sets, and broadcast domains. By placing the European SVM and its LIFs into a dedicated IPspace, you create a logically isolated network environment, ensuring that its traffic cannot mix with other SVMs in different IPspaces. This is the most robust method for enforcing strict network segmentation for compliance.
- 7
During the initial setup of a Cisco UCS 6454 Fabric Interconnect pair, an administrator must decide between End-Host Mode and Switch Mode for Ethernet switching. The upstream network consists of a pair of Nexus 9000 switches configured for vPC. Which two statements accurately describe the implications of choosing End-Host Mode in this scenario? (Select TWO)
Show answer details
Correct answer: A, B
In End-Host Mode, the UCS Fabric Interconnects behave like a host with many network adapters to the upstream network. They do not participate in the Spanning Tree Protocol (STP), which prevents potential STP loops and simplifies the network topology.
A key characteristic of End-Host Mode is that it pins server MAC addresses to specific uplink ports. To achieve active-active uplinks to a vPC pair of Nexus switches, each Fabric Interconnect must have a port-channel to each Nexus switch, and these are bundled into a vPC. This allows for seamless failover and load distribution.
- 8
A FlexPod administrator is provisioning a new UCS Service Profile for a database server that requires SAN boot. The storage team has provisioned a LUN on the NetApp AFF array. When configuring the boot policy, the administrator needs to specify the World Wide Port Name (WWPN) of the target. Where is the correct WWPN for the FC SAN LIF found?
Show answer details
Correct answer: A
The
network interface show -vserver -lif -fields wwpncommand in the ONTAP CLI will display the WWPN of the Fibre Channel Logical Interface (LIF). This is the correct target WWPN that needs to be used in the UCS boot policy and for zoning on the FC switches. - 9
True or False: When performing a non-disruptive software upgrade (ISSU) on a pair of Nexus 9000 series switches configured with vPC, the operational role of the vPC primary switch is automatically transferred to the secondary switch before the upgrade process begins on the primary.
Show answer details
Correct answer: A
This statement is true. A key part of the ISSU process in a vPC environment is to ensure service continuity. Before upgrading the vPC primary switch, the system gracefully transfers the primary role to the vPC secondary peer. This ensures that the secondary switch continues to forward traffic and handle control plane functions while the original primary is upgraded. After the first switch reloads and comes back online, the roles may or may not be switched back depending on the configuration.
- 10
A hospital is expanding its FlexPod infrastructure to support a new Electronic Health Record (EHR) system. The new UCS C-Series servers will connect via iSCSI to a NetApp AFF C190. The network administrator is creating a dedicated VLAN and subnet for iSCSI traffic. According to Cisco and NetApp best practices for iSCSI performance and reliability, which network feature should be enabled on the Nexus switch ports connected to the servers and storage?
Show answer details
Correct answer: B
Enabling Jumbo Frames (setting the Maximum Transmission Unit, or MTU, to 9000 or higher, typically 9216 on Nexus) is a critical best practice for iSCSI. It allows larger payloads per packet, which reduces the number of packets and CPU cycles required on both the initiator (server) and target (storage) to transfer the same amount of data. This significantly improves throughput and efficiency for block storage traffic.
