Skip to content

5V0-2121 HCI Master Specialist Practice Questions

Prepare for 5V0-2121 with more than an answer.

208 questions in the full set20 sample questionsUpdated Mar 13, 2026

Unlock the full exam and previous versions

  • v1Version 1 208 questions Current
  • 5V0-21.19Legacy VMware vSAN 6.7 Specialist Exam 2019 108 questions Locked
  • 5V0-21.20Legacy VMware HCI Master Specialist 61 questions Locked
Exam fee
$250 USD
Level
Master Specialist
Valid for
2 years
Domains covered on the exam 7
  1. Architecture and Technologies
  2. VMware Products and Solutions15%
  3. Planning and Designing35%
  4. Installing, Configuring, and Setup
  5. Performance-tuning, Optimization, and Upgrades20%
  6. Troubleshooting and Repairing20%
  7. Administrative and Operational Tasks10%
  1. 1

    True or False: The vSAN iSCSI Target Service can be used to present vSAN storage to physical servers outside of the vSphere environment.

    Show answer details

    Correct answer: A

    This is true. The primary purpose of the vSAN iSCSI Target Service is to provide block-level storage from the vSAN datastore to external, non-vSphere workloads. This includes physical servers (e.g., for Microsoft Clustering) or other hypervisors that require shared block storage and have an iSCSI initiator.

  2. 2

    Case Study:

    A retail company, ShopFast, has a 2-node vSAN ROBO (Remote Office/Branch Office) cluster at each of its 50 retail stores. These clusters run point-of-sale and inventory management VMs. All stores are connected back to a central data center where the vCenter Server and a single vSAN Witness Appliance are located. The witness appliance is currently serving all 50 ROBO sites.

    Recently, ShopFast acquired a competitor and will be adding 30 more stores, each with its own 2-node vSAN ROBO cluster. The IT team is concerned that the single, existing witness appliance cannot support the new total of 80 ROBO sites. The network latency from the new stores to the central data center is within the supported limits for witness traffic.

    The project goal is to accommodate the new stores' witness component requirements while minimizing the management overhead and resource consumption at the central data center. The existing ROBO sites are running vSAN 7.0 U1 and the new sites will be deployed with the same version.

    What is the most efficient solution for the administrator to implement to support all 80 ROBO sites?

    Show answer details

    Correct answer: B

    A single vSAN Witness Appliance can be configured as a 'Shared Witness' to provide witness components for multiple 2-node vSAN clusters. As of vSAN 7.0 U1, a single shared witness can support up to 64 2-node clusters. While this doesn't cover all 80 sites, the most efficient first step is to enable this feature and add as many new sites as possible. Since the case states they need to support all 80, this implies deploying a second shared witness would be the ultimate solution, but enabling the existing one is the correct, most efficient first action. A single shared witness is far more resource and management efficient than deploying one witness per ROBO site.

  3. 3

    Referring to the ShopFast case study, an administrator at one of the remote stores accidentally disconnects the network uplink for one of the two ESXi hosts. What is the expected behavior for the VMs running on that ROBO cluster?

    Show answer details

    Correct answer: B

    In a 2-node ROBO cluster, if one host becomes isolated from the network (and therefore from the other host and the witness), it loses quorum. The remaining host, which can still communicate with the witness, forms a majority and takes ownership of the vSAN objects. vSphere HA will detect the failure of the VMs on the isolated host and restart them on the active, non-isolated host, ensuring service continuity.

  4. 4

    A vSAN cluster is configured with Deduplication and Compression enabled. An administrator notices that the space savings are lower than expected. Which of the following is a primary prerequisite for data to be deduplicated within a vSAN disk group?

    Show answer details

    Correct answer: C

    vSAN Deduplication and Compression occurs as data is destaged from the write buffer (cache tier) to the capacity tier. It is not an inline process that happens upon initial write. Therefore, data must first land in the write buffer and then be moved to the capacity tier for space-saving techniques to be applied. Furthermore, deduplication happens only within a single disk group, not across the cluster.

  5. 5

    Which three actions should be performed as part of a vSAN cluster upgrade process using vSphere Lifecycle Manager (vLCM) with a single image? (Select THREE).

    Show answer details

    Correct answer: A, C, E

    Before any upgrade, it is critical to run a vSAN Health Check to ensure the cluster is in a healthy, stable state. Attempting to upgrade an unhealthy cluster can lead to failures or data unavailability.

    The desired ESXi version, drivers, and firmware defined in the vLCM image must be compatible with the underlying server hardware, including I/O controllers. Checking the VCG is a mandatory step to prevent unsupported configurations.

    After defining the desired image and performing pre-checks, the core action is to remediate the cluster. vLCM will then orchestrate the entire process, putting hosts into maintenance mode, applying the updates, and bringing them back online in a rolling fashion.

  6. 6

    An administrator needs to replace a faulty capacity disk in a vSAN disk group. The cluster has sufficient free capacity to tolerate the device failure. The administrator has physically replaced the drive in the server chassis. What is the next step the administrator should take in the vSphere Client to add the new disk to the disk group?

    Show answer details

    Correct answer: C

    The vSphere Client provides a streamlined workflow for replacing a failed disk. From the Cluster > Configure > vSAN > Disk Management view, the failed disk will be clearly marked. Selecting this disk will present the option to replace it. The administrator can then select the newly installed, available disk from a list to take its place in the disk group. vSAN will handle the formatting and partitioning.

  7. 7

    A vSAN administrator is troubleshooting a stretched cluster that has experienced a complete failure of the inter-site link between the two data sites. The link to the witness host from both data sites remains fully operational. What is the expected behavior of the cluster in this scenario?

    graph TD subgraph Data Site A (Preferred) H1 & H2 & H3 end subgraph Data Site B H4 & H5 & H6 end subgraph Witness Site Witness end H1 H4 H2 H5 H3 H6 style H1 stroke-width:2px,stroke:red,fill:#FCC style H2 stroke-width:2px,stroke:red,fill:#FCC style H3 stroke-width:2px,stroke:red,fill:#FCC style H4 stroke-width:2px,stroke:red,fill:#FCC style H5 stroke-width:2px,stroke:red,fill:#FCC style H6 stroke-width:2px,stroke:red,fill:#FCC linkStyle 0 stroke-width:4px,stroke:red,stroke-dasharray: 5 5 linkStyle 1 stroke-width:4px,stroke:red,stroke-dasharray: 5 5 linkStyle 2 stroke-width:4px,stroke:red,stroke-dasharray: 5 5 H2 --> Witness H5 --> Witness

    Show answer details

    Correct answer: B

    In a vSAN stretched cluster, when the inter-site link fails but both sites can still communicate with the witness, a decision must be made to keep one site active to prevent a split-brain scenario. The witness, along with the hosts on the preferred site, will form a quorum (majority). The preferred site will remain online and continue running VMs. The non-preferred site will lose the election, its hosts will lose access to the vSAN datastore, and its VMs will be restarted by vSphere HA on the preferred site.

  8. 8

    A financial services company is designing a new 8-node vSAN 7.0 U3 cluster to host a mission-critical, low-latency trading application. The application vendor specifies that storage latency must remain consistently below 1ms. The architect has chosen all-flash NVMe devices for both the cache and capacity tiers. To ensure maximum performance and predictability, which vSAN storage controller configuration represents the best practice for this scenario?

    Show answer details

    Correct answer: C

    For optimal vSAN performance, especially with high-performance NVMe devices, the storage controller should be in pass-through (HBA/IT) mode. This allows vSAN to have direct control over the physical devices, minimizing controller overhead and latency. Using RAID mode introduces an unnecessary layer of abstraction and potential bottleneck. Enabling the controller's cache can interfere with vSAN's caching mechanisms and is not recommended. A high queue depth is beneficial but is a characteristic of a suitable controller, not a configuration mode in itself; pass-through mode is the foundational requirement.

  9. 9

    An administrator is managing a 10-node vSAN cluster and needs to perform firmware updates on a single host's network adapters. To minimize impact on the cluster, the administrator places the host into maintenance mode using the 'Ensure accessibility' option. During the maintenance window, a second, unrelated host in the cluster experiences a sudden power supply failure and goes offline. What is the expected status of the VM objects that had components on both the host in maintenance and the failed host, assuming a standard FTT=1, RAID-1 policy?

    Show answer details

    Correct answer: B

    The 'Ensure accessibility' option does not move all data from the host entering maintenance mode. It only resynchronizes components if an object would become non-compliant (e.g., losing its last replica). For a standard FTT=1, RAID-1 object, components are on different hosts. When the first host enters maintenance, the object is still accessible via its other replica. However, when the second host fails, the object loses its remaining data component and its witness component, resulting in a loss of quorum (less than 50% of components available). This renders the object inaccessible until one of the hosts comes back online.

  10. 10

    A vSAN administrator is troubleshooting a performance complaint on a hybrid vSAN cluster. Using vsantop in the ESXi shell, they observe the following metrics for a specific disk group:

    DGROUP-UUID (naa.xxx):
    ReadCacheHitRate: 15%
    WriteBufferFree%: 95%
    ReadLatency: 3.5ms
    WriteLatency: 0.8ms

    Based on this output, what is the most likely cause of the performance issue?

    Show answer details

    Correct answer: B

    The key indicator here is the very low ReadCacheHitRate of 15%. This means that 85% of read requests are missing the cache and must be fetched from the slower capacity tier (magnetic disks in a hybrid cluster), which explains the higher ReadLatency (3.5ms). A healthy read cache hit rate is typically 90% or higher. The WriteBufferFree% is high (95%), and WriteLatency is low (0.8ms), indicating that writes are not the problem. The issue is a cache miss on reads, pointing to an undersized read cache for the working set of the VMs.

Create an account to continue.