D-PE-OE-01 Dell PowerEdge Operate v2 Practice Questions
Prepare for D-PE-OE-01 with more than an answer.
- Level
- Professional
- Valid for
- Refer to Dell Proven Professional recertification policy
Domains covered on the exam 5
- Server Management22%
- Server Maintenance16%
- Troubleshooting22%
- Server Monitoring20%
- System Administration20%
- 1
A systems operations engineer is managing an isolated edge datacenter with 18 PowerEdge servers running iDRAC 10. Following an automated firmware update cycle to iDRAC 10 version 1.20.80.50, an edge application orchestration tool encounters recurring API authentication timeout issues. The decision is made to roll back the iDRAC firmware to the previously installed firmware build.
The engineer connects to the iDRAC firmware RACADM prompt on the first server and executes:
racadm rollback iDRAC.Embedded.1-1The command fails immediately with a validation error indicating that the rollback cannot proceed in the current configuration. The engineer verifies that:
- The engineer is logged in with an account having Configure privileges.
- Running racadm swinventory confirms that Rollback Version is listed as Available for iDRAC.Embedded.1-1.
- The job queue (racadm jobqueue view) contains no scheduled, running, or staged jobs.
- The iDRAC NIC is currently configured to use Shared LOM mode across the server's embedded Ethernet interfaces.
What action must the engineer perform before the iDRAC firmware rollback operation can succeed?
Show answer details
Correct answer: B
According to Dell iDRAC 10 documentation, if the iDRAC network interface is operating in Shared LOM mode, it must be switched to Dedicated mode before initiating an iDRAC firmware rollback ('racadm rollback iDRAC.Embedded.1-1'). While non-iDRAC device rollbacks require Server Control privilege, iDRAC rollback specifically requires Configure privilege (which the administrator already has). Furthermore, rollback cannot execute if another update is staged or running.
flowchart TD Start([Initiate iDRAC Rollback]) --> CheckQueue{Is another job running/staged?} CheckQueue -->|Yes| Block1[Fail: Clear Job Queue] CheckQueue -->|No| CheckRollback{Rollback Version Available?} CheckRollback -->|No| Block2[Fail: No Prior Version] CheckRollback -->|Yes| CheckNIC{NIC Mode == Shared LOM?} CheckNIC -->|Yes| Block3[Fail: Must Switch to Dedicated NIC Mode] CheckNIC -->|No| CheckPriv{User has Configure Privilege?} CheckPriv -->|Yes| Execute[Proceed with iDRAC Firmware Rollback] CheckPriv -->|No| Block4[Fail: Missing Configure Privilege] - 2
An infrastructure team plans to standardize BIOS and component settings across 50 PowerEdge servers using Server Configuration Profiles (SCP). The team wants to validate attribute syntax and check for potential configuration errors on target servers without rebooting or applying any changes to the running system. Which feature and licensing condition satisfy this requirement?
Show answer details
Correct answer: A
In iDRAC 10, the Server Configuration Profile (SCP) Preview feature ('--preview') creates a validation job that verifies XML/JSON syntax, schema validity, and attribute compatibility without rebooting the server or modifying actual system settings. While SCP export is supported on the base iDRAC Core license, importing or previewing SCP configurations requires an iDRAC Enterprise or Datacenter license.
- 3
True or False: Applying an iDRAC firmware update using the RACADM CLI or the iDRAC web interface requires the embedded Lifecycle Controller to be in an enabled state, whereas executing the iDRAC Dell Update Package (DUP) directly within a supported host operating system does not require the Lifecycle Controller to be enabled.
Show answer details
Correct answer: A
The iDRAC10 User's Guide image-file dependency table, which applies to iDRAC firmware, shows that RACADM updates and iDRAC web interface updates require the Lifecycle Controller to be enabled for both the .d10 image and the iDRAC DUP. The same table shows that running the iDRAC DUP in-band from a supported host operating system does not require the Lifecycle Controller. Both halves of the statement match the documentation, so the answer is True, not False. Redfish is not part of this statement; the table lists its Lifecycle Controller requirement as N/A.
- 4
A PowerEdge server experiences an uncorrectable multi-bit memory error resulting in an automated system restart. An engineer needs to query the hardware-level BMC sensor events to identify the failing DIMM slot, rather than viewing the chronological record of administrative configuration changes. Which RACADM command should the engineer execute?
Show answer details
Correct answer: B
'racadm getsel' displays the System Event Log (SEL), where iDRAC records system hardware events such as this memory fault, so it is the direct way to query the BMC's hardware event history. The Lifecycle log is broader: besides a copy of each SEL entry, it holds configuration changes, firmware updates, audit events and work notes, and 'racadm lclog export' only copies that whole history to a share. 'racadm getraclog' shows the RAC log (iDRAC audit entries such as user logins), and 'racadm jobqueue view' lists jobs in the job queue, so neither reports hardware faults.
graph TD subgraph SEL["System Event Log (racadm getsel)"] S1[System Hardware Events] end subgraph LC["Lifecycle Log (racadm lclog view / export)"] L1[Copy of Each SEL Entry] L2[Configuration and Firmware Update Events] L3[Audit Events and Work Notes] end S1 -->|Also recorded in| L1 - 5
A network security administrator is auditing the remote management configuration of several PowerEdge servers managed by iDRAC 10. The audit reveals that generic LDAP queries are currently being transmitted over plain-text TCP port 389 with STARTTLS. The organization's security policy requires immediate migration to dedicated SSL/TLS-wrapped LDAP (LDAPS) over TCP port 636. Which pair of RACADM commands must the administrator run to meet this requirement?
Show answer details
Correct answer: D
In iDRAC 10, generic LDAP connection settings are managed under the 'idrac.ldap' attribute group. To switch from the default STARTTLS mode on port 389 to dedicated LDAPS on port 636, the administrator must configure 'idrac.ldap.connection' to 'LDAPS' and 'idrac.ldap.port' to '636'. The group 'idrac.security.ldapmode' does not exist in the iDRAC 10 RACADM schema.
- 6
A healthcare provider is deploying 24 Dell PowerEdge R7725 servers to host an Electronic Health Records (EHR) database environment. To satisfy regulatory and internal Zero-Trust security baselines, the out-of-band management controllers must enforce two strict technical controls:
- Centralized directory service authentication integrated with the enterprise Microsoft Active Directory forest for all administrative access.
- Scheduled and on-demand iDRAC verification of the integrity and authenticity of the host BIOS image while the host is powered on (BIOS Live Scanning).
During the hardware intake inspection, the systems engineering team discovers that the servers were delivered with the base factory-default iDRAC 10 license. The management team requests a license evaluation to identify the exact license tier required to fulfill both mandates with minimal excess licensing expense.
Which licensing recommendation correctly addresses the infrastructure requirements?
graph LR subgraph Core["iDRAC 10 Core"] C1[Local User Auth] C2[SCP Export Only] C3[SupportAssist Collection] end subgraph Ent["iDRAC 10 Enterprise"] E1[Virtual Media / Console] E2[SCP Import & Preview] E3[System Lockdown Mode] end subgraph Data["iDRAC 10 Datacenter"] D1[Telemetry Streaming] D2[Custom PCIe Airflow] end Core --> Ent --> DataShow answer details
Correct answer: A
Both the iDRAC10 User's Guide license table and the Security Configuration Guide list directory services (Active Directory and LDAP) as unavailable on the factory-default Core license and included from Enterprise upward. BIOS Live Scanning, which checks the integrity and authenticity of the BIOS image in the primary ROM while the host is powered on, requires an iDRAC Datacenter license in both documents. Because the Datacenter license includes every Enterprise feature, it is the lowest single tier that meets both mandates. Enterprise alone (option B) lacks BIOS Live Scanning, Core (option C) lacks both features, and an OpenManage Enterprise plugin (option D) does not replace the iDRAC Datacenter license that BIOS Live Scanning requires.