Skip to content

DSDSC-200 Dell SC Series Storage Professional Exam Practice Questions

Prepare for DSDSC-200 with more than an answer.

115 questions in the full set12 sample questionsUpdated Sep 16, 2021
Level
Professional
Domains covered on the exam 5
  1. Dell SC Series Storage Architecture and Components20%
  2. Volume Management and Provisioning25%
  3. Monitoring, Alerting, and Reporting20%
  4. Snapshot Management (Replay)20%
  5. Storage Array Deployment and Troubleshooting15%
  1. 1

    An engineer needs to configure a server HBA port to connect to the storage array via FC. The storage is configured in legacy port mode.
    The engineer needs to provide full connectivity from the storage array to the server HBA port.
    Which two zone configurations on the FC switch should the engineer use to meet the requirement? (Choose two.)

    Show answer details
  2. 2

    A site contains many volumes that are all listed under the Volumes icon. These volumes are mapped to several servers. The engineer needs to be able to more easily manage the volumes for replay scheduling. The engineer does NOT want to duplicate any work when assigning the volumes to a replay profile.
    How should the engineer accomplish the task?

    Show answer details

    Correct answer: B

    B

  3. 3

    A customer has an 8 TB database. Half of the data is hot with very frequent access. The other half of the data is older, infrequently used cold data. The customer buys (12) 800 GB SLC Solid State Drives, and puts them in a new disk folder called “Database”. The customer then creates volumes for this database in the Database disk folder using the recommended storage profile.
    After this database has been running for 1 month, the Statistics tab for the database volumes shows 100% of the space is on Tier 1. The customer expected that half of the data would be on Tier 1 and the rest moved to lower tiers.
    What is the problem?

    Show answer details

    Correct answer: B

    B

  4. 4

    An administrator needs to replicate data to an off-site Storage Center. Data on both sides must always match. The administrator must have the data sent to the remote system as soon as the data is written. If the communication to the remote system fails, all writes to the local system must stop.
    Which option should the administrator choose to meet the requirements?

    Show answer details

    Correct answer: C

    C

  5. 5

    What are two effects of pre-allocating space on a volume? (Choose two.)

    Show answer details

    Correct answer: A, C

    A, C

    A, C

  6. 6

    A customer has a newly installed storage array. The customer needs to proactively monitor and report storage utilization on a regular basis.
    Which customizable, proactive tool should be configured to perform this task?

    Show answer details

    Correct answer: A

    A