D-VXR-DY-01 Dell VxRail Deploy Practice Questions
Prepare for D-VXR-DY-01 with more than an answer.
- Level
- Deploy Specialist
- Valid for
- 3 years
Domains covered on the exam 10
- VxRail Physical Components4%
- VxRail Deployment Planning12%
- Using VxRail Configuration Tools4%
- VxRail Hardware Installation and Initialization8%
- VxRail Network Environment Requirements and Initialization8%
- Deploying the VxRail Cluster24%
- VxRail Post-Deployment Procedures18%
- VxRail Cluster Upgrade and Expansion10%
- VxRail Troubleshooting6%
- VxRail REST API6%
- 1
A financial services company is deploying a new VxRail cluster. Due to strict compliance requirements, all data must be encrypted at rest from the moment the cluster is created. Which VxRail and vSAN architecture combination supports this 'Day 1' encryption requirement?
Show answer details
Correct answer: B
A key feature of vSAN Express Storage Architecture (ESA) is its ability to enable encryption during the cluster creation process. vSAN OSA, by contrast, can only have encryption enabled as a post-deployment task after the datastore has been created. Therefore, for a strict 'Day 1' encryption requirement, vSAN ESA is the correct choice.
- 2
After a successful VxRail deployment, an administrator needs to configure a custom vSAN storage policy for a mission-critical database application. The policy must ensure the application can survive the failure of any two hosts (N+2) and should use RAID-6 for maximum space efficiency where possible. Which settings should be configured in the new storage policy?
Show answer details
Correct answer: D
The requirement to survive the failure of two hosts directly translates to a 'Failures to tolerate' (FTT) setting of 2. The requirement for space efficiency points to Erasure Coding (RAID-5/6) rather than Mirroring (RAID-1). With FTT=2, vSAN will automatically use a RAID-6 (double parity) configuration, which meets both requirements.
- 3
An administrator needs to add two new, identical nodes to an existing 6-node all-flash VxRail cluster. Which of the following are mandatory prerequisites before initiating the expansion process from VxRail Manager? (Select THREE)
Show answer details
Correct answer: A, C, E
VxRail Manager discovers and adds new nodes via their iDRAC. The nodes must be physically installed and their iDRACs must be accessible on the network before the expansion wizard can be run.
Before any cluster modification, it is mandatory to run the built-in health checks to ensure the cluster is stable and ready for the change. Attempting to expand an unhealthy cluster is not supported.
Just as with initial deployment, proper name resolution is critical for adding new nodes. The IP addresses that will be assigned to the new hosts must have corresponding A and PTR records in DNS before starting the expansion.
- 4
A vSAN health check on a VxRail cluster reports an error in the 'Physical Disk' category, indicating that a capacity-tier SSD has failed on one of the nodes. The administrator has physically replaced the failed drive with an identical, Dell-certified replacement. What is the next step the administrator should take within the vSphere Client to incorporate the new drive into the vSAN datastore?
Show answer details
Correct answer: B
After a physical disk replacement, vSAN does not automatically claim the new disk. The administrator must go into the vSphere Client, navigate to Cluster > Configure > vSAN > Disk Management, find the host with the replaced drive, and manually add the new, unclaimed disk to the correct disk group. This action triggers vSAN to start using the disk and begin any necessary data resynchronization.
- 5
Case Study:
A regional hospital group is implementing a new electronic health record (EHR) system on a 6-node all-flash VxRail P-Series cluster using vSAN OSA. The deployment was successful, and initial performance testing is underway. The vSAN administrator observes that while overall latency is good, there are periodic, brief spikes in read latency across the cluster that coincide with periods of heavy reporting queries from the EHR application.
The current vSAN configuration uses a single disk group per node, each with one cache-tier SSD and five capacity-tier SSDs. The default storage policy is being used, which is RAID-1 Mirroring with FTT=1. The administrator suspects the cache tier may be a bottleneck during these read-intensive reporting periods.
To mitigate these read latency spikes and improve overall read performance for the EHR system, which architectural change should the administrator propose?
graph TD subgraph Current Node Config CG[Cache Tier: 1x SSD] CapG[Capacity Tier: 5x SSDs] CG --> CapG end subgraph Proposed Change CG1[Cache Tier: 1x SSD] CapG1[Capacity Tier: 2x SSDs] CG2[Cache Tier: 1x SSD] CapG2[Capacity Tier: 3x SSDs] CG1 --> CapG1 CG2 --> CapG2 end Current Node Config -->|Becomes| Proposed ChangeShow answer details
Correct answer: C
In an all-flash vSAN OSA configuration, the cache tier is used for both write buffering and as a read cache. With a single disk group, all I/O for that node must pass through a single cache device. By reconfiguring each node to have two disk groups (e.g., one cache + 2 capacity, one cache + 3 capacity), the cluster gains an additional cache device per node. This doubles the available read cache capacity and throughput per node, effectively distributing the read I/O load and mitigating the latency spikes caused by the reporting queries.
- 6
A deployment engineer is finalizing the network plan for a new 8-node VxRail P-Series cluster that will leverage vSAN Express Storage Architecture (ESA). The customer's top-of-rack switches are Dell S5248F-ON models. To maximize performance and ensure redundancy, which physical network cabling and VDS uplink configuration represents the best practice?
Show answer details
Correct answer: D
vSAN ESA requires a minimum of 10GbE networking, but 25GbE is strongly recommended for optimal performance. The best practice for redundancy and performance is to use two 25GbE ports connected to separate physical switches in an active/active configuration on the vSphere Distributed Switch (VDS). This avoids a single point of failure at the switch level and utilizes all available bandwidth. LACP provides link redundancy but not switch redundancy. Using 10GbE is suboptimal for ESA, and separating traffic across different active/standby pairs is less efficient than an active/active model.
- 7
During the deployment of a VxRail cluster into a customer-managed vCenter, the process fails during the step where ESXi hosts are added to the vCenter inventory. The error message indicates 'Cannot contact the specified host. The host may not be available on the network'. A manual check confirms that the ESXi management IP addresses are pingable from the vCenter Server Appliance. Which of the following are the most likely causes of this issue? (Select TWO)
Show answer details
Correct answer: B, D
TCP port 902 is required for the vCenter Server to communicate with the hostd agent on ESXi hosts for management purposes. If this port is blocked, vCenter cannot add or manage the host, even if ICMP (ping) is allowed.
While not always a hard failure point, missing reverse DNS records are a very common cause of host-to-vCenter communication issues. vCenter often relies on proper forward and reverse name resolution to establish a trusted connection with hosts.
- 8
A consultant has completed a VxRail deployment and is performing post-deployment validation. They run the vSAN Health Check and observe a warning under the 'Network' category related to 'All hosts have a vSAN vmknic configured'. Upon investigation, one of the four nodes in the cluster does not have a vmknic tagged for vSAN traffic. What is the most direct and appropriate method to resolve this issue?
Show answer details
Correct answer: C
VxRail Manager is responsible for maintaining the cluster's configuration consistency. Manually changing configurations in vCenter can lead to configuration drift. The correct, VxRail-aware method is to use the built-in VxRail Manager functionality, such as the 'Add Host Networking' or similar Day 2 configuration wizards, to re-apply the intended network profile to the non-compliant host. This ensures the change is tracked by VxRail and aligned with its desired state.
- 9
A DevOps team wants to automate the process of scaling out their VxRail clusters. They plan to use the VxRail REST API to add a new, pre-racked and cabled node to an existing cluster. What is the correct high-level sequence of API calls required to accomplish this?
Show answer details
Correct answer: B
The correct sequence involves first discovering available, unconfigured nodes. The
GET /v1/hosts?unconfigured=trueendpoint is designed for this. Next, a specification for the expansion must be created using a POST to an endpoint like/v1/cluster/expansion/specor by providing the full spec in the final call. Finally, the expansion is initiated with a POST to the primary/v1/cluster/expansionendpoint, including the specification of the node to be added. The other options either miss steps or have them in the wrong order. - 10
When using the VxRail Configuration Portal to plan a deployment, it is mandatory to generate a JSON configuration file that will be consumed by VxRail Manager during the initialization process.
Show answer details
Correct answer: B
While using the VxRail Configuration Portal and generating a JSON file is a best practice for complex or repeatable deployments, it is not mandatory. An engineer can perform the initial cluster configuration interactively through the VxRail Manager UI wizard without pre-creating a JSON file.
