Skip to content

HQT-4180 Hitachi Vantara Qualified Professional - Vsp Midrange Family Installation Practice Questions

Prepare for HQT-4180 with more than an answer.

207 questions in the full set20 sample questionsUpdated Aug 11, 2025
Exam fee
$100 USD
Level
Professional
Valid for
3 years
Domains covered on the exam 8
  1. System Architecture & Components15%
  2. Back-End Architecture12%
  3. System Installation25%
  4. System Maintenance20%
  5. Configuration Changes10%
  6. Firmware Upgrades8%
  7. Remote Ops Monitoring5%
  8. Storage Management Tools5%
  1. 1

    A regional bank is installing a new Hitachi VSP E990. The solution architect has designed a back-end configuration using SAS SSDs. The primary requirements are the highest possible data protection against double drive failures within a RAID group and acceptable write performance for mixed workloads.

    After reviewing the requirements, the installation engineer must decide on the appropriate RAID level for the primary storage pools. The business can tolerate the capacity overhead associated with stronger protection.

    Given these specific requirements, which RAID configuration is the most appropriate choice for the installer to implement?

    Show answer details

    Correct answer: B

    The primary requirement is protection against double drive failures. RAID-6 is specifically designed for this purpose, using two independent sets of parity data to allow the RAID group to remain online even if two drives fail simultaneously. While RAID-10 offers excellent performance, it can only guarantee survival of a single drive failure in the worst-case scenario (if two drives in the same mirror pair fail). RAID-5 only protects against a single drive failure. Therefore, RAID-6 is the only option that directly and unequivocally meets the customer's main data protection requirement.

  2. 2

    A manufacturing company is setting up a new VSP E590. The IT administrator, who is new to Hitachi storage, asks the installer about the different management tools available. The administrator's primary need is a single, unified web interface for day-to-day provisioning tasks, such as creating volumes, managing host groups, and monitoring basic system health.

    The company does not have the broader Ops Center suite deployed yet. The installer needs to point the administrator to the correct embedded tool for these routine tasks.

    Which management tool should the installer identify as the primary interface for these day-to-day activities?

    Show answer details

    Correct answer: D

    Hitachi Storage Navigator is the embedded, web-based graphical user interface (GUI) that runs on the Service Processor (SVP) of the VSP midrange system. It is the primary tool for performing day-to-day storage administration and provisioning tasks directly on a single array. It provides an intuitive interface for creating volumes, managing pools, configuring host connectivity, and monitoring health, perfectly matching the administrator's stated requirements. The other tools listed serve more specialized purposes like deep performance analysis, automation, or low-level hardware maintenance.

  3. 3

    While performing post-installation checks on a VSP E790, an engineer notices that several drives in a newly created RAID-6 group are in a 'Blocked' state. All physical connections have been verified as correct. What is a common reason for drives to enter this state after initial formatting?

    Show answer details

    Correct answer: B

    During the formatting of a RAID group, the VSP system performs a thorough check of the drive media. If it encounters a significant number of unrecoverable media errors or predicts that a drive is unreliable, it will proactively place the drive in a 'Blocked' state to prevent it from being used in production. This is a protective measure to ensure data integrity. The solution is to replace the blocked drives.

  4. 4

    What is the function of the System Option Mode (SOM) in a VSP midrange system?

    Show answer details

    Correct answer: C

    System Option Mode (SOM) is a special, text-based maintenance mode that provides access to low-level system parameters and service functions. It is not used for routine daily operations but is required for specific tasks like certain configuration changes, hardware replacements, or system recovery procedures that cannot be performed through the standard Storage Navigator GUI.

  5. 5

    Which statement accurately describes the relationship between physical drives, RAID groups, and Dynamic Provisioning pools in a VSP Midrange system?

    graph TD subgraph "Physical Layer" D1(Drive 1) D2(Drive 2) D3(Drive 3) D4(Drive 4) D5(Drive 5) D6(Drive 6) end subgraph "Logical Layer" RG[RAID Group] Pool[DP Pool] LDEV(LDEV/Volume) end D1 --> RG D2 --> RG D3 --> RG D4 --> RG RG --> Pool Pool --> LDEV

    Show answer details

    Correct answer: C

    The architectural hierarchy is as follows: Physical drives are grouped together to form a RAID group, which provides data protection. Then, the usable capacity from one or more RAID groups is aggregated to create a Dynamic Provisioning pool. Finally, logical volumes (LDEVs) are created from the capacity available in the pool. This layered approach provides flexibility and abstracts the logical storage from the physical hardware.

  6. 6

    An installer is performing a pre-installation site survey for a new Hitachi VSP E790 with two expansion drive boxes. The customer's data center uses top-of-rack power distribution units (PDUs) with IEC C19 outlets. The VSP E790 requires four power connections for the controller chassis and two for each drive box. What is the primary power-related consideration the installer must verify with the data center manager?

    Show answer details

    Correct answer: B

    The most critical power consideration is ensuring the total power draw (amperage) of the storage system does not overload the PDUs or the circuit breaker. While phase separation is a best practice for redundancy, exceeding the total capacity is a primary safety and operational risk that must be verified first. The number of outlets and network port availability are secondary concerns compared to the fundamental power capacity.

  7. 7

    During the initial configuration of a VSP E990, an installer is using the Maintenance Utility to set up the system. The customer's security policy requires that all system-generated alerts and notifications be sent to a central Syslog server. Which specific section within the initial setup workflow must the installer configure to meet this requirement?

    Show answer details

    Correct answer: C

    The Alert Notification Settings section of the initial configuration process is specifically designed for configuring methods of sending system alerts, including SNMP traps, email notifications, and Syslog forwarding. The installer must enter the IP address and port of the customer's Syslog server in this section. Network Settings are for the system's own IP, Date and Time is for NTP, and User Accounts is for local access.

  8. 8

    An installer has just replaced a faulty cache module in a VSP E590. After the physical replacement, the system alerts still show the component as failed. What is the most likely reason for this discrepancy, and what is the immediate next step?

    Show answer details

    Correct answer: B

    For many component replacements in VSP systems, especially those related to memory or processing, the fault status must be manually cleared using the maintenance utility (like Storage Navigator) after the physical replacement is complete. The system does not always automatically clear the historical alert. This action confirms the repair and resets the component's status to normal. Rebooting the controller is a drastic step and usually not required.

  9. 9

    A customer is expanding their VSP E790 by adding a new drive box populated with SAS SSDs. The existing system uses RAID-6 (6D+2P) for all its pools. The customer wants the new drives to be part of a new, separate pool optimized for a high-transaction database application. Which RAID configuration should the installer recommend for the new pool to maximize write performance?

    Show answer details

    Correct answer: C

    For high-transaction database applications, write performance is critical. RAID-1 (mirroring) provides the best write performance because it does not have the write penalty associated with calculating and writing parity bits like RAID-5 and RAID-6 do. While it has a 50% capacity overhead, it meets the primary requirement of maximizing write performance for the specified workload. RAID-5 and RAID-6 are better suited for read-intensive or capacity-focused applications.

  10. 10

    Which two statements accurately describe the function and characteristics of the Service Processor (SVP) in the VSP Midrange family? (Select TWO)

    Show answer details

    Correct answer: B, D

Create an account to continue.