Skip to content

HPE0-S51 HPE Data Center Solutions Practice Questions

Prepare for HPE0-S51 with more than an answer.

127 questions in the full set8 sample questionsUpdated Jan 20, 2026
Exam fee
$150 USD
Time limit
90 minutes
Questions on the exam
60
Passing score
63 (scale 0-100)
Level
ATP (Accredited Technical Professional)
Valid for
3 years
Domains covered on the exam 6
  1. Foundational Architectures10%
  2. HPE Products and Solutions18%
  3. Solution Planning and Design25%
  4. Solution Installation and Configuration25%
  5. Solution Management, Monitoring, and Troubleshooting15%
  6. Solution Optimization7%
  1. 1

    You are installing a HPE MSA storage system and need to connect the power cooling module (PCM).What should you do to ensure power redundancy? A.Ensure that a physical service processor is properly connected to each PCMB.Verify that each cooling fan is cabled to a separate controllerC.Connect each PCM within a shelf to a different power distribution unit (PDU)D.Connect redundant power cords from the PCM controller to independent power supplies

    Show answer details

    Correct answer: C

  2. 2

    A customer needs to purchase a redundant pair of SAN switches for their virtualization environment. The customer requires a total of eight 16 Gbps FC storage ports and eighteen 8 Gbps FC host attachments.Which switch does meet the customer's needs at the lowest cost? A.HPE 8/24 SAN Switch 16-port Switch with an 8-port Upgrade LicenseB.HPE StoreFabric SN6010C 12-port Switch with an On Demand Port Activation LicenseC.HPE 8/24 SAN Switch 16-port SwitchD.HPE StoreFabric SN6010C 48-port Switch

    Show answer details

    Correct answer: B

  3. 3

    A field technician is upgrading an HPE ProLiant DL380 Gen10 server. The customer has purchased an HPE Smart Array P408i-a SR Gen10 controller to provide hardware RAID for a new set of SAS drives. The technician needs to physically install the controller in the server chassis.

    Based on the controller model name and the provided simplified system board layout, where must the technician install this specific controller?

    graph TD subgraph "ProLiant DL380 Gen10 System Board (Simplified)" CPU1[CPU Socket 1] CPU2[CPU Socket 2] DIMMs1[DIMM Slots] DIMMs2[DIMM Slots] PCIe1[PCIe Riser Slots] FlexibleLOM[FlexibleLOM Slot] AROC[AROC Connector] end CPU1 --- DIMMs1 CPU2 --- DIMMs2 PCIe1 --- AROC FlexibleLOM --- AROC

    Show answer details

    Correct answer: B

    The 'a' in the controller model P408i-a stands for 'AROC' (Advanced RAID on Chip), previously known as 'Array on Chip'. This designates it as a modular controller that installs into a dedicated, proprietary slot on the system board, not a standard PCIe slot. This design saves a valuable PCIe slot for other expansion cards.

  4. 4

    You are working in a data center with multiple servers and need to update the iLO 5 user names and passwords on a regular basis.Which tool enables you to streamline and automate this process? A.iLO Amplifier PackB.Central Management ConsoleC.Agentless ManagementD.RESTful API

    Show answer details

    Correct answer: A

Create an account to continue.